HID3000

Remote I/O System “Point to Bus” I/O

“Point to Bus” System
HiD3000 with integral Instrinsic Safety, drastically reduces field cabling and saves cabinet space.
HiD3000 termination boards can even be installed in a “Zona 2” hazardous area and accept inputs from “Zona 0” with the isolated intrinsic safety inputs.

Plug & Play Modules
Plug & Play module allows to mix I/O signal types to match all field applications. Analog and digital signals can be mixed in any combination on each termination board, avoiding the need to marshal field wiring.

Conversion of the process signal into digital from takes place within every HiD3000 module, eliminating  external signal to signal conversion and increasing overall loop accuracy.

Download full datasheet (PDF) | Installation sheet (PDF)

Field Device Model No. of Ch.
Part Number
Hazardous Area Signal Comment
download Pdf
Analog IN/OUT HiD3010 Ch. 2 - PN 186323 4-20 mA (15 V) floating supply
to Smart or non-Smart two wire
Transmitters.
Channels may be either: 2 analog inputs or
2 analog outputs or
1 analog input + 1 analog output.
scarica il pdf
4-20 mA signal to I/P converters,
electrovalve actuators and displays.
HART® signals are routed to external multiplexer
and hand held communicator (HHC).
Low Level IN HiD3040 Ch. 4 - PN 186324 Thermocouple or mV. Configurable for mV; TC; RTD or Pot inputs (2-3-4 wire).
scarica il pdf
Ch. 2 - PN 186324 RTD or Potentiometer.
Digital IN HiD3824 Ch. 4 - PN 186322 Dry Contact or Proximity Switch. Each channel configurable for Line Fault Detection.
scarica il pdf
Digital OUT HiD3878 Ch. 2 - PN 186320 40 mA at 11 V to drive a
solenoid valve, audible or
visual alarm (LED).
Each channel configurable for Line Fault Detection.
scarica il pdf
Frequency IN HiD3891 Ch. 1 - PN 186325 Frequency measurement
unit with “proximity switch”
or “voltage input”
electrical interface.
Up to 2 KHz input frequency programmable
integration time (≥ 1 second) line fault detection
(open and short circuit).
scarica il pdf
Communication Gateway PBDP1 PN 186326 Profibus DP slave module. All PROFIBUS DP data rates up to 12 M bit/sec.
scarica il pdf
MBRT PN 186318 Modbus RTU slave module. All MODBUS RTU slave, data rates up to 115.2 K bit/sec.
scarica il pdf
HART® Multiplexer
hart
MUX2700 Ch. 32    
scarica il pdf
Standard Termination Boards
er

Intrinsic Safety 16 position Termination Board

Model:

3116/HAT-2G/SABUS-R-HART (PN129647).

Board configuration:
- 1 to 16 modules HiD3000.
- 1 or 2 Gateways Modbus RTU or Profibus DP.
- 1 MUX2700 HART® Multiplexer (optional).

Connection:
- Hazardous Area 9 blue terminals per module (including shield).
- Safe Area: Fieldbus Communication Link.
- Power Supply: Redundant terminals for 24 Vdc supply.
- RS232 connectors for local access to each communication Gateway.
- Test Points accessing each HART® signal.
- RS485 connection terminals for MUX2700 connections HART® Multiplexer (identified as A, B, GND) 6 terminals for multidrop.

Mounting:
- Safe or Hazardous Area (Zone 2) location.
- Surface mounting or DIN-rail 35 mm using DINK1 accessory.

er

Non I.S. 16 position Termination Board

Model:

3116/FCT-2G/SABUS-R-HART (PN473202).

Board configuration:
- 1 to 16 modules HiD3000.
- 1 or 2 Gateways Modbus RTU or Profibus DP.
- 1 MUX2700 HART® Multiplexer (optional).

Connection:
- Field instrumentation: 9 grey terminals per module (including shield).
- System: Fieldbus Communication Link.
- Power Supply: Redundant terminals for 24 Vdc supply.
- RS232 connectors for local access to each communication. Gateway
- Test Points accessing each HART® signal.
- RS485 connection terminals for MUX2700 connections HART® Multiplexer (identified as A, B, GND) 6 terminals for multidrop.

Mounting:

- Safe Area location.
- Surface mounting or DIN-rail 35 mm using DINK1 accessory.

er

I.S. and non-I.S. 15 position Termination Board

Model:
3115/10HAT-5FCT-2G/SABUS-R-HART (PN130299).

Board Configuration:
- 1 to 15 modules HiD3000.
- 1 or 2 Gateways Modbus RTU or Profibus DP.
- 1 MUX2700 HART® Multiplexer (optional).

Connection:
- Field instrumentation:
- Hazardous Area: 10 modules, each one connecting to 9 blue terminals (including shield).
- Safe Area: 5 modules, each one connecting to 9 grey terminals (including shield).
- System: Fieldbus Communication Link.
- Power Supply: Redundant terminals for 24 Vdc supply.
- RS232 connectors for local access to each communication Gateway.
- Test Point accessing each HART® signal.
- RS485 connection terminals for MUX2700 connections HART® Multiplexer (identified A, B, GND) 6 terminals for multidrop.

Mounting:
- Safe Area location.
- Surface mounting or DIN-rail 35 mm using DINK1 accessory.

er

Intrinsic Safety 8 position Termination Board

Model:
3108/HAT-2G/SABUS-R-HART (PN130300).

Board configuration:
- 1 to 8 modules HiD3000.
- 1 or 2 Gateways Modbus RTU or Profibus DP.
- 1 MUX2700 HART® Multiplexer (optional).

Connection:
- Hazardous Area: 9 blue terminals per module (including shield).
- Safe Area: Fieldbus  Communication Link.
- Power Supply: Redundant terminals for 24 Vdc supply.
- RS232 connectors for local access to each communication. Gateway.
- RS485 connection terminals for MUX2700 connections HART® Multiplexer (identified as A, B, GND) 6 terminals for multidrop.

Mounting:
- Safe or Hazardous Area   (Zone 2) location.
- Surface mounting or DIN-rail 35 mm using DINK1 accessory.

er

Non I.S. 8 position Termination Board

Model:
3108/FCT-2G/SABUS-R-HART (PN473200).

Board configuration:
- 1 to 8 modules HiD3000.
- 1 or 2 Gateways Modbus RTU or Profibus DP.
- 1 MUX2700 HART® Multiplexer (optional).

Connection:
- Field instrumentation: 9 blue terminals per module (including shield).
- System: Fieldbus Communication Link.
- Power Supply: Redundant terminals for 24 Vdc supply.
- RS232 connectors for local access to each communication Gateway.
- RS485 connection terminals for MUX2700 connections HART® Multiplexer (identified as A, B, GND) 6 terminals for multidrop.

Mounting:
- Safe Area location.
- Surface mounting or DIN-rail 35 mm using DINK1 accessory.



Approvals
Authority
Certificate/File no.
Standard
Approved for
PDF
ex
CESI 03 ATEX 061
EN 50.014
EN 50.020
EN 50.284
EN 50.021
II (1) GD
[EEx ia] IIC

II 3 (1) GD - EExnA IIC; T4
pdf
ex
1222682
C22.2 No. 157
C22.2 No. 213
E79-0
E79-11
E79-15
Cl. I, Div. 1;
Cl. I, Zone O: [Exia] IIC.
Cl. I, Div. 2
Cl. I, Zone 2: ExnA IIC; T4
pdf
ex
POCC IT. ГБ05: B00387
GOST 12.2.007.0-75
GOST P 51330.10-99
[Ex ia] IIC
pdf
ce
DECLARATION OF CONFORMITY ->
pdf

Last update of this page : 7-11-2007